Herunterladen Inhalt Inhalt Diese Seite drucken

Fault Tables - Elmo Rietschle V Serie Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für V Serie:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

• Damage, in particular to:
• Ventilation grilles
• Screw connections
• Media lines
• Electrical cables
• Leaks
• Loose objects
• Loose screw connections or fastenings
• Contact protection on live parts
If defects and hazards become apparent during the inspection, the pump must be shut down immediately.
The pump may only be put into operation if it is in perfect condition.
The chapter 8.1 must be followed.
7.1

Fault tables

The following tables describe possible causes of faults and the activities required to rectify them. In the
event of faults that cannot be rectified using the following instructions, please contact Gebr Gardner Den-
ver Schopfheim GmbH.
The pump does not reach the required vacuum
Possible cause
Leakage in the pressure/vacu-
um line
Slider worn out
Filter dirty
Resistance in the supply line too
high
Resistance in the supply line too
high
Resistance in the supply line too
high
The motor runs in the wrong di-
rection of rotation if the pump is
not working correctly and emits
loud noises
Tab. 5
Fault Table: The pump does not reach the required pressure/vacuum
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
TROUBLESHOOTING / FAULT RECTIFICATION
Review
Visual inspection of the pressure/
vacuum line elements (e.g. pipe-
work, fittings, hose clamps)
Visual inspection for damage
Measure slider width
Check filter contamination
Check the dimensions of the
supply line
Check supply lines for blocka-
ges, kinks and deformations
Check throttle elements for ope-
ning condition
Check the direction of rotation
using the direction of rotation
arrow
Troubleshooting
Replacing the faulty supply line
elements
Remove the slider, check and re-
place if damaged or if the minimum
width is not reached
Clean / replace filter
Carry out dimensioning in accordan-
ce with the operating instructions;
further support from Elmo Rietschle
Service
Remove foreign objects from the
media line. Repair supply lines if
necessary
Open throttle elements if necessary
The motor installation must be cor-
rected by a qualified electrician.
www.elmorietschle.com © Gardner Denver Schopfheim GmbH
Tel. 071 918 60 60, Mail: v-g@prematic.ch
25
|

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

V-ktr 61V-ktr 81V-ktr 101V-ktr 141

Inhaltsverzeichnis