OUTDOOR UNIT INSTALLATION
Step5:
Connecting Refrigerant Pipe
5.1 Unscrews the valve cover, grasp and press it down gently to take it down(if the valve cover is
applicable).
5.2 Remove the protective caps from the end of valves
.
5.3
Take off the plastic cover in the pipe ports and c
the connecting pipe and make ensure the port is clean.
5.4 After align the center, rotate the flare nut of the connecting pipe to tighten the nut as tightly as
possible by hand.
5.5
At the gas valve, turn the nut at position 1 with a fix wrench to position 2.
Repeat this step for liquid valve. Please use
(Refer to the torque requirements table on section INSTALLATION PRECAUTIONS)
Take down the valve cover
heck whether there is any sundry on the port of
the torque values in the torque requirements table.
22