MAINTENANCE
Clean the
filter
Tip: When you find accumulated dust in the filter, please clean the filter in time to
ensure the clean, healthy and efficient operation inside the air conditioner.
First, loosen the knob on the middle of louver and bend the louver outwards to take
it out.
Then, grasp both sides of bottom plate push downwards to take down the bottom
plate.
Finally, loosen the buckle of deflector assembly with your thumb and take it out.
Wipe the air duct and fan assembly with a clean and wrung wet rag.
Cleaning
Clean the removed parts with soapy water and air dry it.
of inner
After cleaning, restore the removed parts in turn.
air duct
Louver
When the air conditioner is not in use for a long time, do the following work:
Take out the batteries of the remote controller and disconnect the power supply of
the air conditioner.
Service and
When starting to use after long-term shutdown:
maintenance
1. Clean the unit and filter screen;
2. Check whether there are obstacles at the air inlet and outlet of indoor and outdoor
units;
3. Check whether the drain pipe is unobstructed;
Install the batteries of the remote controller and check whether the power is on.
Take out the filter
from the unit
<40
(104 )
Clean the filter with
soapy water and air dry it
Deflector assembly
Bottom plate
26
Opposite to the
direction of taking
out the filter