Herunterladen Diese Seite drucken

Fronius TransPocket 125 VRD Bedienungsanleitung Seite 67

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

(1)
The characteristic parameter sets the slope for the falling welding current characteristic.
When welding cellulose electrodes, the characteristic slope is the most important criterion
for the weld properties.
If the cellulose electrode has a tendency to stick, adjust the characteristic parameter to a
higher level (flat characteristic).
Arc-force dynam-
NOTE!
ic parameter
The arc-force dynamic parameter can only be set when carrying out the MMA weld-
ing process.
(1)
U (V)
1 A/V
3 A/V
(2)
2 A/V
(3)
0
1
2
Value
4 A/V (factory setting)
2,7 A/V
1,3 A/V
0 A/V (no LED lights up)
Level 2 (2.7 A/V) is set in this example
U (V)
0
1
2
3
+13A
+40A
+27A
Legend for the figure:
(1)
Open circuit voltage
(2)
Constant current
(3)
Set welding current
-
Level 0 = soft, low-spatter arc (vertical
characteristic = constant current)
-
Level 3 = hard, stable arc (flat charac-
teristic)
I (A)
3
Setting
Level 3
Level 2
Level 1
Level 0
The arc-force dynamic parameter is used to
influence the short circuit current at the mo-
ment of droplet transfer.
If the rod electrode has a tendency to stick,
adjust the arc-force dynamic parameter to a
higher level.
-
Level 0 = particularly soft, low-spatter
arc
-
Level 3 = particularly hard, stable arc
Legend for the figure:
I (A)
(1)
Open circuit voltage
(2)
Set welding current
(2)
67

Werbung

loading