The Setup menu
Setting options
The following welding parameters can be set in the set-up menu:
-
-
Functional princi-
The welding parameters can be set in 4 levels.
ple
The number of indicators lit corresponds to the level reached.
Setting the weld-
How to set a parameter is exemplified using the arc-force dynamic parameter for the
ing parameters
MMA welding process.
The welding parameters are retained even if the mains plug is disconnected.
Characteristic pa-
rameter
The characteristic parameter can only be set when using the MMA welding with CEL
electrode process.
66
Arc-force dynamic (for the MMA welding process only)
Characteristic (for the MMA welding process with CEL electrode only)
Several indicators light up
three
two
one
None
Level 2 is set in this example
Press the Process button to select the MMA welding process
1
Keep the Process button held down
2
The preset level is displayed for 1 second
Keeping the Process button held down will raise the arc-force dynamic
3
parameter one level every second.
Release the Process button when the desired level has been reached.
4
The selected level is stored and the MMA welding process is indicated.
NOTE!
NOTE!
Settings
Level 3
Level 2
Level 1
Level 0