4
5
6
7
Risk of injury and damage from electric shock.
As soon as the mains switch is in the "I" position, the electrode in the welding torch is live.
Make sure that the electrode does not touch any persons or electrically conducting or
earthed parts (e.g. the housing, etc.).
8
TIG welding
1
2
3
Igniting the arc
1
2
3
4
5
Equip the welding torch in accordance with the welding torch operating instructions
Plug the current plug of the grounding (earthing) cable into the (+) current socket and
turn it clockwise to latch it in place
Use the other end of the grounding (earthing) cable to establish a connection to the
workpiece
Plug in the mains plug
CAUTION!
Move the mains switch to the "I" position
All the indicators will light up briefly
Select TIG welding using the Process button
the TIG welding indicator lights up
Select the amperage using the adjusting dial
Start welding (ignite the arc)
Place the gas nozzle down on the ignition location, ensuring there is a gap of approx.
2 to 3 mm (5/64 to 1/8 in.) between the tungsten electrode and the workpiece
Actuate the torch trigger
Shielding gas flows
Gradually tilt the welding torch up until the tungsten electrode touches the workpiece
Raise the welding torch and pivot it into its normal position
The arc ignites.
Carry out welding
65