Herunterladen Diese Seite drucken

Fronius TransPocket 125 VRD Bedienungsanleitung Seite 62

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

MMA welding
Safety
Operating the equipment incorrectly can cause serious injury and damage.
Do not use the functions described until you have thoroughly read and understood the fol-
lowing documents:
► these operating instructions
► all the operating instructions for the system components, especially the safety rules
An electric shock can be fatal.
If the power source is connected to the mains electricity supply during installation, there is
a high risk of very serious injury and damage. Before carrying out any work on the device
make sure that:
► the power source mains switch is in the "O" position
► the power source is unplugged from the mains
Preparation
1
2
3
4
5
6
7
Risk of injury and damage from electric shock.
As soon as the mains switch is in the "I" position, the rod electrode in the electrode holder
is live. Make sure that the rod electrode does not touch any persons or electrically conduct-
ing or earthed parts (e.g. the housing, etc.).
8
Manual metal arc
1
welding
2
62
WARNING!
WARNING!
Move the mains switch to the "O" position
Disconnect the mains plug
Plug the grounding (earthing) cable into the (+) or (-) current socket, depending on the
type of electrode, and latch it in place
Use the other end of the grounding (earthing) cable to establish a connection to the
workpiece
Plug the electrode holder cable into the (+) or (-) current socket, depending on the type
of electrode, and latch it in place
Insert the rod electrode into the electrode holder
Plug in the mains plug
CAUTION!
Move the mains switch to the "I" position
All the indicators will light up briefly
Select one of the following processes using the Process button:
Manual metal arc welding
the manual metal arc welding indicator lights up
MMA welding with CEL electrode
CEL
the MMA welding with CEL electrode indicator lights up
Select the amperage using the adjusting dial