PROOF W6
Program description

Cleaning stop:

DIP switch 3
Serves to disable automatic activation prior to cleaning.
DIP switch 3 ON = Cleaning stop function enabled (default setting).
DIP switch 3 OFF = Cleaning stop function disabled.
Enable cleaning stop
Approach the infrared sensor
(below the thermostat knob)
with your hand. Wait until the
water starts and then stops
flowing.
Disable cleaning stop
The fitting will resume normal
operation 3 min after the
sensor has remained un-
triggered.
To instantly end the cleaning
stop, perform the same steps
used to enable the function.
Wall tap control
Werkseinstellung:
ON
ON
OFF
OFF
1 2 3 4 5 6
ON
ON
OFF
OFF
1
2 3 4 5 6
ON
ON
OFF
OFF
1
2 3 4 5 6
ON
ON
OFF
OFF
1
2
3 4 5 6
If the auto shutdown
program is enabled
ON
(DIP switch 2 OFF), you
OFF
1
2
3 4 5 6
can only enable the
cleaning stop within
the first 3 s after trig-
gering the water flow.
WimTec OCEAN W6
EN
1 2
3
4 5 6
1 2 3
4
5 6
1 2 3 4
5
6
!
1 2 3 4 5
6
29

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis