Herunterladen Inhalt Inhalt Diese Seite drucken

WimTec PROOF W6 Montageanleitung Und Bedienungsanleitung Seite 21

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PROOF W6
Configuring the programs & functions
Regulator controls:
C.
Range control
User detection range preset to
30 cm (configurable from
15 cm – 30 cm).
Sets the infrared sensor range.
Note on range setting:
Most operating modes (depending on the DIP switch configuration) will stop the
water flow as soon as you remove your hands from the sensor area. In particular
as regards shallow, large ceramic basins, the basin itself can cause the sensor to
trigger continuously. This is evidenced by the water flow continuing for a long time
or the fitting triggering on its own. In extreme cases, the fitting will trigger by itself,
water will flow until the water arrest time has been reached, and then the device
will no longer trigger. If this happens, you need to reduce the sensor range. If the
range is too low, the infrared sensor may no longer be able to properly detect your
hands. In most operating modes, this will make it impossible to activate the fitting.
To remedy this situation, increase the sensor range.
DIP switches:
Program activation – DIP switches 1 and 2:
Program
Fully automatic mode
Auto shutdown
Function activation – DIP switches 3–6:
DIP switch
Function
3
Cleaning stop
4
Continuous flow
5
Stagnation rinse
6
Shut-off delay ON = 5 s / OFF
D.
Time control
for safety flow arrest
preset to 1 min
(configurable from 10 s to
10 min). Auto shutdown: confi-
gurable from 10 s to 60 s.
After the configured maximum
flow time has elapsed, the
water stops automatically.
DIP switch 1
ON
1)
OFF
1)
DIP switch 2
Description
ON
Page 27
OFF
Page 28
Description
Page 29
Page 30
Page 31
1)
= 2 s
Wall tap control
E.
Interval control
for stagnation rinse
(setting range 3 h – 48 h).
If the wall fitting has not been
used for the set period, the de-
vice will automatically perform
a 10 s rinse.
In general, the
following applies:
Move counterclock-
wise to decrease
the setting. Move
clockwise to incre-
ase the setting.
Program
1)
or functions
already
configured
ex factory.
WimTec OCEAN W6
EN
!
21