Herunterladen Diese Seite drucken

Sharp VL-C780S Serviceanleitung Seite 172

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

a
VL-C7805/H/X
VL-C7400E
VL-C690S/H/x
VL-C6400E
® Test mode
:
Test modes of 8 types are allowed to be set depending on the voltage entered in pin (22).
SW No.
Test contents
Sensor on/off
1
Whole sensor off
Sensors are off except cassette controller SW,
<—
DEW, and battery detection sensors.
L/M 5 sec. sensor is inhibited allowing checking of | Onexcept VM 5
substrates without mechanism. (Do not connect
. | sec. sensor.
mechanism in this mode.)
j
Adjustment error in the battery sensor isshownin
| On except the
the counter display in the view finder.
battery sensor.
Error display
Past errors are shown in the counter display inthe | All sensors are on.
view finder.
Tracking display
Tracking data are shown in the counter display
All sensors are on.
section, and the power LED flashes if the tracking
is in the center.
Servo phase control
Phase control of capstan and drum is inhibited.
All sensors are on.
inhibition
(For measurement of closed loop of servo)
7
Adjustment mode for
Adjustment mode of camera
(VCR stop)
service
Reel sensor off
Only the reel sensor is off.
On except the reel
sensor.
Normal mode
Normal operation
Ail sensors are on.
11

Werbung

loading

Diese Anleitung auch für:

Vl-c690s