Herunterladen Diese Seite drucken

Grundfos DPK Montage- Und Betriebsanleitung Seite 9

Vorschau ausblenden Andere Handbücher für DPK:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
8. Approvals
The standard version DPK pumps have been tested
by TÜV according to EC Council Machinery Directive
98/37/EC, registration no. AM 5014341 3 0001 and
report no. 13009106 001.
9. Type key
The pump can be identified by the type designation
stated on the pump nameplate. See section
7.
Nameplate.
Code
Example
DPK
Drainage pump
Impeller design:
.
Semi-open impeller
V
Vortex impeller
Free passage:
65
Maximum solids size [mm]
Pump outlet:
80
Nominal diameter of pump outlet port [mm]
Code for output power, P2:
22
P2* = Code number from type designation / 10 [kW]
Equipment:
-
Standard
S
Sensor(s)
Motor pole:
2
2-pole motor
4
4-pole motor
Frequency:
5
50 Hz
6
60 Hz
Voltage and starting method:
0D
380-415 V, DOL
1D
380-415 V, Y/D
0E
220-240 V, DOL
1E
220-240 V, Y/D
*
Exception: Code 075 = 0.75 kW.
DPK.
V
65.
80.
22.
S.
4.
.5
0D
9