Herunterladen Diese Seite drucken

Renishaw RSP3 Installations- Und Bedienungsanleitung Seite 19

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 57
RSP3 installation and user's guide
www.renishaw.com
RSP3-1 / 2 / 3 / 4
Characteristic
Probe attributes
Measurement range
Overtravel range
X, Y
+Z
-Z
Resolution
Spring rate
Weight
RSP3-1
RSP3-2
RSP3-3
RSP3-4
Effective stylus length range
RSP3-1 + RSH3-1
RSP3-2 + RSH3-2
RSP3-3 + RSH3-3
RSP3-4 + RSH3-4
Mounting
Crash protection
±X, ±Y, ‐Z
+Z
Signal outputs
Change rack options
RCP TC-2
FCR25 with FCR25 front spacer kit
Interface options
Issued 10 2019
Requirements
Scanning with 3-axis measurement (X, Y, Z) and 3-axis touch-trigger
±0.5 mm deflection in all directions in all orientations
2 mm
1.7 mm
1.2 mm
Capable of <0.1 μm
Nominally 0.6 N/mm - when using shortest specified stylus
Nominally 0.2 N/mm - when using longest specified stylus
86 g (3.03 oz) (excluding stylus holder and stylus)
90 g (3.17 oz) (excluding stylus holder and stylus)
94 g (3.32 oz) (excluding stylus holder and stylus)
101 g (3.56 oz) (excluding stylus holder and stylus)
Always observe the specified stylus range for the scanning module
being used. Use Renishaw's M3 range of styli.
EWL 20 mm - 50 mm (0.79 in - 1.97 in) using 20 mm - 50 mm stylus
EWL 44 mm - 99 mm (1.73 in - 3.90 in) using 20 mm - 75 mm stylus
EWL 114 mm - 194 mm (4.49 in - 7.64 in) using 20 mm - 100 mm
stylus
EWL 214 mm - 394 mm (7.64 in - 15.51 in) using 20 mm - 200 mm
stylus
Magnetised kinematic coupling
Via break out of probe or stylus holder
Via integral bump-stop design
Non-linear and non-orthogonal analogue outputs - rate gain and
resolution are not fixed
Thermally controlled change port for probe changing only
This single port unit mounts on the MRS / MRS2 rack
Triple port unit which mounts on the MRS / MRS2 rack
UCC S5