Herunterladen Diese Seite drucken

o&o LOG-BR Installations Und Bedienungs Seite 15

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
In the case of standard installations where no advanced functions are required, it is possible to proceed to
manual storage of the transmitters, making reference to programming table A and to the example for basic
programming.
1) If you wish the transmitter to activate output 1, press pushbutton PR1, otherwise if you wish the
transmitter to activate output 2, press pushbutton PR2.
2) When LED DL1 starts blinking, press hidden key on the transmitter, LED DL1 will remain continuously lit.
3) Press the key of the transmitter to be memorized, LED DL1 will fl ash quickly to indicate that it has been
memorized successfully. Flashing as normal will then be resumed.
4) To memorize another transmitter, repeat steps 2) and 3).
5) To exit memorizing mode, wait for the LED to go off completely or press the key of a remote control that
has just been memorized.
IMPORTANT NOTE: ATTACH THE ADHESIVE KEY LABEL TO THE FIRST MEMORISED TRANSMITTER
(MASTER).
In the case of manual programming, the fi rst transmitter assigns the key code to the receiver; this code is
necessary in order to carry out subsequent cloning of the radio transmitters.
This mode is used to copy the keys of a transmitter already stored in the receiver memory, without acces-
sing the receiver.
The fi rst transmitter is to be memorised in manual mode (see paragraph 11.4).
a) Press hidden key on the transmitter already memorised.
b) Press key T on the transmitter already memorised, which is also to be attributed to the new transmitter.
c) Within 10 s., press hidden key on the new transmitter to be memorised.
d) Press key T to be attributed to the new transmitter.
e) To memorise another transmitter, repeat the procedure from step (c) within a maximum time of 10
seconds, otherwise the receiver exits the programming mode.
f ) To copy another key, repeat from step (a), having waited for the receiver to exit the programming mode
(or after disconnecting the receiver from the power supply).
12. TROUBLESHOOTING GUIDE
1) ACQUISITION MODE AND POWER OUTAGES
Acquisition mode is activated automatically after a power outage. The barrier moves slowly in this mode to locate the position of the
mechanical end stops.
The control unit exits acquisition mode automatically when an opening cycle and a closing cycle are completed in succession.
The control unit automatically adjusts the motor deceleration ramp in relation to the weight of the barrier and the ambient temperature.
It may take a number of opening and closing cycles for the ramp to be set correctly. During this period, the bar may not stop smoothly
at the end of travel.
2) ENCODER CONNECTIONS
RED
BLACK
BLUE
13. ATTENTION
NOTE: Installation should always include all the accessories necessary to ensure operation in accordance with current
laws and standards, utilising always and only original parts.
Always follow the manufacturer's instructions for using and installing this equipment as he cannot be considered liable for
any damages or injury arising from an improper or unreasonable use.
The constructor declines all responsibility for any inaccuracies contained in this leafl et and reserves the right to make
alterations at any time without prior notice.
LOG-BR - Installation and operation manual
11.4 MANUAL PROGRAMMING
11.5 SELF-LEARNING MODE PROGRAMMING
- 15 -
EN
Hidden key
Hidden key
T2
T1
T4
T3

Werbung