8. PROGRAMMING
1) After connecting all mechanical and electrical components securely, manoeuvre the barrier manually using the specifi c release key.
2) Disconnect power, then adjust the two bolts setting the barrier open and barrier closed end stops.
3) Check that the bar is balanced correctly: the bar should remain in equilibrium at an angle between 45-50°.
4) Re-engage the barrier with the drive motor with the lock key.
5) The travel acquisition cycle counts and memorises the number of pulses received from an encoder on the motor drive shaft.
IMPORTANT: do not obstruct the movement of the barrier during this cycle.
9. SETTING THE TRIMMERS
PM1: PAUSE TIME. Sets the pause time between 2 and 120 sec.
PM2: SPEED. Sets manoeuvre time.
PM3: PRE-MANOEUVRE WARNING LAMP FLASH TIME. Sets the pre-manoeuvre warning fl ash time between 0 and 10 sec.
10. WORKING WITH A BUFFER BATTERY
KIT-BATT allows the automation system to operate even when the mains power supply is disconnected for a short time.
Consult the KIT-BATT installation manual.
11. RADIO RECEIVER
- Max. n° of radio transmitters that can be memorized:....................................................................................2048
- Frequency:................................................................................................................................................433.92MHz
- Code by means of:....................................................................................................................Rolling-code algorithm
- N° of combinations:..........................................................................................................................................4 billion
By means of jumpers J1 and J2 it is possible to select the 1st and 2nd radio channel function on START or APRI and AP.PED or
CHIUDI respectively (fi gura paragraph 2).
Use an antenna tuned to 433MHz. Connect the tuned antenna to the antenna terminals using RG58 coaxial cable .
LOG-BR - Installation and operation manual
PRELIMINARY CHECK AND ACQUISITION CYCLE
11.1 RECEIVER TECHNICAL SPECIFICATIONS
11.2 RADIO CHANNEL FUNCTIONALITY
11.3 ANTENNA INSTALLATION
ANTENNA
SHIELD
antenna cable RG58
- 14 -