To refill bottles proceed as follows:
- set the refill pressure on the pressure switch (1);
- fit the hose connector (a) to the bottle valve (b);
- screw in the fixing knob (c) until it is completely tightened;
- check that the bleed valve (f ) is closed by rotating it clockwise;
- open the valve (d) by rotating it anticlockwise;
- start the compressor;
- open the valve (e) by rotating it anticlockwise;
- once refilling has been completed wait for automatic shutdown of the
compressor with the pressure switch;
- close valves (d) and (e) by rotating them clockwise;
- open the bleed valve (f ) by rotating it anticlockwise until all the residual
air in the fitting has been expelled;
- unscrew the fixing knob (c) by rotating it anticlockwise;
- disconnect the bottle coupling.
MU-SSE-0920
b
e
SUPER SILENT EVO
DEUTSCH
Um die Flaschen zu füllen, wie hier beschrieben vorgehen:
- am Druckwächter (1) den Fülldruck einstellen;
- den Anschluss (a) des Füllschlauchs am Flaschenventil (b) montieren;
- den Feststellknopf (c) bis zum kompletten Anziehen festdrehen;
- überprüfen, dass das Entlüftungsventil (f ) geschlossen ist, indem es im
Uhrzeigersinn gedreht wird;
- das Ventil (d) durch Drehen gegen den Uhrzeigersinn öffnen;
- den Kompressor starten;
- das Ventil (e) durch Drehen gegen den Uhrzeigersinn öffnen;
- nach erfolgtem Füllvorgang warten, bis sich der Kompressor mit
Druckwächter automatisch ausgeschaltet hat:
- die Ventile (d) und (e) durch Drehen im Uhrzeigersinn schließen;
- das Entlüftungsventil (f ) durch Drehen gegen den Uhrzeigersinn öffnen,
bis die gesamte Restluft aus dem Anschluss abgelassen ist;
- den Feststellknopf (c) durch Drehen gegen den Uhrzeigersinn lockern;
- den Anschluss von der Flasche trennen.