Graphic Data Manager
"Application -
Batch mode"
menu items
Reset batch number
only if "Batch number" -
"Automatic"
"Inputs - Digital
inputs" menu
items
Function
Select the required function. Digital inputs are High active, this means the described effect is achieved
by a high input. Low = -3...+5 V, High = +12...+30 V
The following functions are available:
"Switched off": digital input is not active.
"Control input": various control functions can be activated for batch mode using the digital input.
Channel ident.
Description of the function of this input (e.g. "Batch 1 start"). User input: 16-digit.
Factory setting: Digital x
Action
Set up the function of the control input for batch mode:
"Start/end batch x": starts/stops external analysis (analysis only runs while the signal is High).
Measured value acquisition for the graphic display continues. Batches are also started/stopped using
this function.
"Reset batch number x": resets the automatically generated batch number to 0 (for Low -> High
change)
"Batch x limit values on/off": switch the batch' s limit values on/off.
Copy settings
Copies settings from actual channel to selected channel. The last two positions of the channel ident.
of the target channel are replaced by this channel number.
Configurable parameters
(factory settings are highlighted in bold)
Select the digital input that resets the batch number to its default
value.
Note: The assigned input is automatically pre-configured!
Picklist: Switched off, Digital input x
2.3
Setup - Inputs - Digital inputs
Settings for digital inputs for batch mode.
NOTICE
Only settings relevant for batch mode are described here. For all the other signal analysis
functions, see the Operating Instructions.
Fig. 5:
Setup - Inputs - Digital inputs - Digital input x
Configurable parameters
(factory settings are highlighted in bold)
Device configuration, application setup
16068/000 to
16068/003
40000/000 to
40000/013
40010/000 to
40010/013
40085/000 to
40085/013
40110/000 to
40110/013
Direct
access
code
Direct
access
code