SETTINGS
If the rudder reacts too nervously, the Resp factor set is too small.
If the vessel wanders around the specified course too much, the Resp factor set is too large.
It is useful to increase this factor in heavy seas, and to reduce it in calm waters. The Resp factor can be set
from 0 to 20.
Automatic adjustment
Special programming allows the LOGIC PILOT to react automatically to changing ambient conditions.
This programming causes the autopilot to select the optimum settings for the rudder factor (Rud), the rudder
response band (Resp), the counter rudder (C/R) and the trimming rate (Trim) under the prevailing ambient
conditions.
You can activate the automatic adjustment function by setting the rudder response band (Resp) to zero.
Example:
4 x
If the value for Resp is set to 0, fine tuning takes place automatically.
If the ambient conditions then change (e.g. the wind moves aft following a change of course, or the wave
direction changes), the steering behaviour is automatically adjusted to suit the new conditions.