5.2.3. Battery installation
ENG
Steadily reinsert the battery into the unit body until the battery is locked in
place by the latch.
5.3. Belt replacement
The CleanAIR
AerGO
®
®
you to replace the belt easily and quickly. Bend the belt at the joint to its
limit position (towards the rear of the unit) until the locking mechanism is
exposed. After releasing the lock (by pulling outwards from the unit), you
can remove the belt freely. Repeat the same procedure for the other side
of the belt.
When installing a new belt, simply push the belt axis into the clamping
mechanism of the unit until it is locked by the latch. Repeat the same pro-
cedure for the other side of the belt.
CAUTION! YOU CANNOT INTERCHANGE THE BELT SIDES!
6. Possible faults
If any fault occurs or if the air supply decreases or increases suddenly and
the user is in a contaminated area, they must leave the area and check
the following:
• that the unit is assembled correctly;
• the battery condition;
• the battery charger function;
• the level of the clogging of the filters;
• that the air hose is not damaged. It is crucial to ensure that the hose
cannnot catch on protruding objects at work and that a crack cannot
occur;
• that the face sealing on the protective hood is in order.
Fault
Possible cause
The PAPR unit
Flat battery
does not work
(check: does the unit
at all
start with another,
working battery?)
Fault in the motor,
electronics or power
connector
The PAPR unit
Air hose or air line
does not supply
clogged
a sufficient
amount of air
Air leaks
(low air flow)
The filter is clogged
The PAPR unit
The filter is clogged
only runs for
a short time
The battery is low
The battery
Fault in the charger
cannot be
charged
Damaged battery
connector
The battery
The battery life is over
cannot be fully
charged
7. Storage
All parts of the CleanAIR
-10 °C and 55 °C, with relative air humidity between 20 and 95% Rh.
Batteries will self-discharge during storage. Therefore, it is recommended
to charge the battery for 1 hour at least every 3 months. The optimal bat-
tery charge level for longer storage is between 50 - 70% of capacity. After
longer storage time it is necessary to repeat 3 charging cycles to reach
battery's full capacity.
6
system is equipped with a mechanism allowing
Recommendation
Charge the battery
(if the problems per-
sists, check the battery)
Return to manufacturer
for repair
Check and remove the
possible obstruction
Check all sealing ele-
ments and connections
and check that the hose
is not damaged and has
no leaks
Replace the filter
Replace the filter
Charge the battery (if
the problem persists,
check the battery)
Contact supplier
Check the battery
contact
Install a new charged
battery
system must be stored at temperatures between
®
8. Warranty
The warranty ensures that you will receive a replacement if a product has
any manufacturing or material defects that appear within 12 months of
the date of purchase. The warranty period for batteries is 6 months from
the date of purchase. The warranty claim must be reported to the sales
department/retailer. At the same time, proof of purchase must be submit-
ted (i.e. an invoice or certificate of delivery). The warranty can only be
acknowledged if no interventions into the powered respiratory unit and
charger have been made. The warranty does not cover defects caused by
the late replacement of filters or by using a filter which was damaged by
cleaning or being blown through.
The manufacturer strongly recommends to perform periodical inspections
in CleanAIR
authorized service center. Inspections should be done ac-
®
cording the local legislation and at least once in every two years.
9. Technical data
Notified body for CE approval:
Occupational Safety Research Institute, v.v.i.
Testing laboratory No. 1024
Jeruzalémská 1283/9, 110 00 Prague 1, Czech Republic
Notified body 1024
Declaration of Conformity is available at: https://www.clean-air.cz/doc
Air flow
Operation* / charging time
Weight including filters and
battery
Unit noise
Battery type
Battery life span
Belt size
Recommended temperature
range at work
Recommended air humidity
range at work
Recommended storage
conditions
*) at 160 lpm with brand new PRSL filters and fully charged battery
10. List of parts and accessories
Ordering No.:
Description
710060
Light flexi hose QuickLOCK™ - CA40x1/7"
310013
Battery Li-Ion Standard 14,4V / 2,6Ah
310023
Battery Li-Ion Heavy Duty 14,4V / 5,2Ah
310030
Battery charger
300030
Protection set (2× prefilter, 2× arrester, 2× cover)
300020
Spark arrester (pack of 10 pcs)
300010/2
Particle filter P R SL (pack of 2 pairs)
300015
Prefilter CleanAIR
300357
Combined filter AerGO
300364
Combined filter AerGO
(pack of 2 pcs)
300368
Combined filter AerGO
(pack of 2 pcs)
300025
Odour filter (pack of 10 pcs)
320092
Leather comfort belt CleanAIR
300092
Comfort padded belt (AerGO)
300093
Comfort belt and harness (AerGO)
160 lpm (manufacturer´s minimum
design flow rate)
210 lpm (maximum flow rate)
< 10 h / < 3 h (standard battery)
< 20 h / 5,5 h (Heavy Duty battery)
980 g
Max. 62 dB
Li-Ion 14,4 V / 2,6 Ah (standard)
Li-Ion 14,4 V / 5,2 Ah (Heavy Duty)
500 charging cycles
60 cm to 150 cm around waist
+10°C to +40°C
20% to 95% Rh.
-10°C to +55°C
AerGO
(pack of 10 pcs)
®
®
A1P R SL (set of 2 pcs)
®
A1B1E1P R SL
®
A1B1E1K1P R SL
®
AerGO
®
®