"23° C U = 15,109V"
"00:07 I=
0.000A"
If the temperature limits are exceeded or not reached during the process, the con-
cerned programme will be interrupted and TMP will be displayed for temperature.
TMP
C= 17.4mAh
St12V D=
0.0mAh
43° C
U= 12.109V
00:01 I=
0.000A
As soon as the temperature is once again within the admissible limits, the program
continues.
This charging station is provided with a memory backup. This means that the pro-
gramme and the cumulated capacity values of the accumulator are saved in the case
of power failure. Therefore, never replace the accumulator if the device is turned off,
because otherwise the charging station would then take over the data which are not
valid any more and would determine false values for the new accumulator!
Take note that the time between connecting and disconnecting should be at least 20
seconds.
If the charging station is turned off during the setting of the charging or discharging
parameters, the setting process will start anew.
CAUTION!
False settings can damage the accumulator and the charging station: the accumula-
tor is either charged incompletely or overcharged. Any warranty will lapse in such
cases!

Operation CT-8000Pb

This process-controlled high-tech charging station by Voltcraft (r) Plus will always
put your lead accumulators into the optimum charging state and ensure a signifi-
cantly higher lifespan. This is guaranteed by the temperature-dependent final charge
voltage and the pulsed charge current of up to 80 Ampere, which counteracts the
age-related sulfating of the lead disks in the accumulator and the related capacity
loss.