Herunterladen Diese Seite drucken

Hitachi CENTRAL STATION PSC-A32MN Installations- Und Betriebshandbuch Seite 44

Vorschau ausblenden Andere Handbücher für CENTRAL STATION PSC-A32MN:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 181
Operation
5.2.3.3 Swing Louvre Direction
1 Select the target group for the change of swing louvre direction at the "Monitor (All Groups)" or "Monitor (Block)" screens. The
screen with the settings for the selected group is displayed on the touchscreen.
Monitor (All Groups)
(1)
2 By tapping " " or " " of the "LOUVRE", the swing louvre direction changes alternatively as shown below.
: Auto swing operation is started.
AUTO
3 Tap "Monitor screen" to return to the "Monitor" screen.
?
N O T E
By tapping "<" or ">" at the detailed setting screen, the Swing Louvre Direction is switched to another group in the same block.
Control Restricted (Run/Stop Only) : In case of "Enable", each Setting Change is for all Groups or Blocks.
Setting Change is not possible for each Group.
Depending on the model of the Air Conditioner, the setting may not be possible or may be calibrated automatically.
Louvre position on LCD and the actual louvre position do not always match during the auto swing operation.
The actual Swing Louvre Direction may not stop immediately after the switch is pressed.
If the settings are mixed when multiple groups are selected, the display remains blank.
36
PMML0332A rev.0 - 05/2015
LCD indication
AUTO
Auto
COOL
DRY
Swing
Auto
HEAT
Swing
FAN
(3)
Angle range
Angle range
(2)
Monitor (Block)
(1)

Werbung

loading