Herunterladen Inhalt Inhalt Diese Seite drucken

ELCOM RTD112Y Anleitung Seite 41

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

RTD112Y
Applications
APPLICATION N° 3: call button (via "Call" command
and Z1/Z2 potential-free inputs)
The SIP relay is used as a call device (doorbell, alarm):
• a (Call) push-button is connected to the SIP relay Z0 input and calls the defi-
ned extension/call group,
• the contacts (associated with the 24 V supplied by the relay) are connected
to the SIP relay Z1 and/or Z2 potential-free inputs and, when these contacts
close, call the defined extension/call group.
Configuration:
On the ISS-300 intercom SIP server, configure the SIP relay as an outdoor
device (device type: custom).
In the SIP relay "Quickstart" menu, select "SIP" and fill in:
• the relay SIP user ID field (e.g. 202),
• the relay SIP authentication PIN (default password: 202abc).
These parameters are the usernames previously configured on the ISS-300
and which define the SIP relay on the network.
www.elcom.de
SUBNET
Z0 / Z0G
Using the Videofon in-
terface setting on your
s m a r t p h o n e / t a b l e t ,
choose an entrance in
the "Entrance and Came-
ra" menu and configure
the ID SIP address allo-
cated to the SIP relay (in
our example: 202).
Subject to technical changes
ISS-300
24V
Z1 / Z1G
12-
12-
Z2 / Z2G
24 V
24 V
SIP CALL
MAINNET