Herunterladen Inhalt Inhalt Diese Seite drucken

ELCOM RTD112Y Anleitung Seite 36

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

RTD112Y
Expert configuration/Functions and applications
General
• The SIP relay is protected by default by a very simple password (1234). This
must be modified the first time you connect up. Enter a new password and
click on "Save" to validate.
• The Web interface language (English by default) can also be configured.
Rebooting the product
This function can be used to reboot the SIP relay.
36
Functions and applications
The SIP relay offers multiple operating possibilities and can be controlled
via various installation devices in the IP network.
The functions that are mainly used are:
• activation of relays K1 and/or K2 on receipt of SIP notifications or on inter-
ception of a UDP type command from the door module with, for example:
- APPLICATION N° 1: door opening, automatic control or other type of sys-
tem command (following an indoor call)
- APPLICATION N° 2: secondary signalling (following an outdoor call)
• triggering of call or SIP notifications following activation of input contact Z0,
Z1 or Z2 for example:
APPLICATION N°3: call button (via "Call" command and Z1 and Z2 potential-
free inputs)
Other secondary functions can be used such as:
• activation of relays K1 and/or K2 on receipt of a UDP type command from the
door module with, for example:
APPLICATION N° 4: latch and/or lighting command (via IP door module)
• activation of relays K1 and/or K2 on activation of a Z0, Z1 or Z2 input contact
with, for example:
APPLICATION N° 5: SIP relay command (via "Call" command)
• activation of relays K1 and/or K2 following a network fault (loss of connecti-
vity or power supply) with, for example:
APPLICATION N° 6: SIP relay switching on system failure.
• activation of relays K1 and/or K2 on receipt of an HTTP request. An "HTTP
request" has the specific quality of being able to run at the same time as
another SIP relay is being used with, for example:
APPLICATION N° 7: SIP relay command via HTTP request.