RTD112Y
Connection and status
Indicators, relay connections and control devices
PoE Ethernet port
PoE
PoE power supply
according to IEEE
802.3af
230 V/16 A max.
K1/2
potential-free
(changeover) relay
C
NC
www.elcom.de
PoE
INPUT
NETWORK
"Call"/command input
ZO
ZOG
Output voltage
OUT +
24 VDC/1 W max.
OUT -
2 potential-free (optocoupler)
Z
1/2
inputs (input voltage range/
12-24 VAC/VDC)
Z
1/2 G
Subject to technical changes
LED status indicators
Power (green) Steady lighting: the device is powered and working.
Link (green)
Steady lighting: the SIP relay is connected to the network.
Call (green)
Steady lighting: the Z0 contact is activated upon closing.
SIP (red)
Brief flashing: the relay is not connected to the IP intercom SIP
server.
Steady lighting: the relay is connected to the IP intercom SIP
server.
Z1
Power
Z2
Link
K1
Call
SIP
K2
Z1-Z2 (green) Steady lighting: the contact is activated when a voltage
ranging between 12 V and 24 V (VAC/VDC) is applied.
K1-K2 (green) Off: the contact is not activated.
Steady lighting: the contact is continuously activated.
27