If the device shall be lowered from the ceiling or high joists, professional trussing systems have to be used.
The device must never be fixed swinging freely in the room.
Caution: Devices in hanging installations may cause severe injuries when crashing down! If you have
doubts concerning the safety of a possible installation, do NOT install the device!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the device's
weight.
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
The maximum drop distance must never exceed 20 cm.
A safety bond which already held the strain of a crash or which is defective must not be used again.
For overhead use, always install an appropriate safety bond. You must only use safety bonds and quick links
complying with DIN 56927, shackles complying with DIN EN 1677-1 and BGV C1 carbines. The safety
bonds, quick links, shackles and the carbines must be sufficiently dimensioned and used correctly in
accordance with the latest industrial safety regulations (e. g. BGV C1, BGI 810-3).
For overhead rigging in public or industrial areas, a series of safety instructions have to be followed that this
manual can only give in part. The operator must therefore inform himself on the current safety instructions
and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Before taking into operation for the first time, the installation has to be approved by an expert!

5.4 Rearranging the spots

If required, the spots can be rearranged to the upper side of the control unit. For this loosen the fixations
screws on the lower side so that the spots can be removed. Then loosen the fixation screws on the upper
side, rearrange the spots and tighten all fixation screws.

5.5 Attaching further light effects

The light set offers mounting points for attaching further light effect units (e.g. spot lights, flower effects or
lasers). For this loosen the fixation screw on the upper side, attach the light effect through its bracket and
tighten the fixation screw.