fCw wALL-MOUNTED fAN COIL UNIT
The Aermec fCw fan coil unit is made with materials of superior quality in strict compliance with safety regu-
lations. The "fCw" is easy to use and will have a long life.
The fan coil unit is a terminal unit for
conditioning internal air both in winter
and summer.
The fCw fan coil unit for wall
mounted installation concentrates high
technological and functional charac-
teristics that make it the ideal climate
control unit for all environments.
The supply of climate controlled air
is immediate and distributed through-
out the room; fCw generates heat if
included in a heating system with a
boiler or heat pump but may also be
used in the summer as an air condi-
tioner if the system has a water chiller.
Unit configuration
By choosing the appropriate options it is possible to select the model to suit the specific system requirements:
1 2 3
Code
fCw
versions
• 2v version with 2-way valve fitted
inside.
Microprocessor controller.
Wired control panel PFW2 or remote
control TLW2.
• 2vN version with 2-way valve fitted
inside.
Standard control or VMF System.
MAIN CHARACTERISTICS:
• EUROvENT Certification
• The response to the commands is
immediate if the room temperature
and the temperature of the water in
the system so allows
• Tangential three-speed fan assembly
• Very quiet operation
• Aesthetic design
• Cream colour
• Display on panel front
• Horizontally adjustable discharge air
blades
The fan coil unit is designed to ensure
maximum compliance with safety
regulations.
Several versions of FCW fan coil units
are available in order to satisfy all
types of installations:
- with internal 2-way-valve,
- with internal 3-way-valve
- without valve.
Each version is available:
- With microprocessor controller
(requires the addition of the PFW2
wired control panel accessory or the
TLW2 remote control accessory.)
- Without microprocessor controller
4 5
Size
21
2v (2-way valve fitted inside)
31
3v (3-way valve fitted inside)
41
vL (without valve)
• 3v version with 3-way valve fitted
inside.
Microprocessor controller.
Wired control panel PFW2 or remote
control TLW2.
• 3vN version with 3-way valve fitted
inside.
Standard control or VMF System.
• Horizontal deflector blades to
vertically adjust discharge air.
Manually adjustable only for units
without microprocessor controller.
For units with microprocessor
controller adjustable only via PFW2
wired control panel or TLW2 remote
control
• Ease of installation with hydraulic
and condensate drain connections
adjustable in several directions
• Routine maintenance is limited to
wh i ch t h e n r e q u i r e s a c a b l e
connected accessory panel or
connection to the accessories of the
VFM system (the VMF-E0 and VMF-
E1 thermostats cannot be installed
internally to the fan coil unit).
In particular, the possibility to be
integrated into the vMf system allows
the control of a single fan coil unit
with accessories, up to the control of
the fan coil unit installed in a complex
network.
6 7
Valve
Microprocessor Controller
(Blank) with controller
N without controller
• vL without valve version.
Microprocessor controller.
Wired control panel PFW2 or remote
control TLW2.
• vLN without valve version.
Standard control or VMF System.
periodic cleaning of the air filter
• F u l l c o m p l i a n c e w i t h s a f e t y
regulations.
IFCW3LJ 1210 - 5375700_01
8
29