Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - EdilKamin MIMI’ Installation, Betrieb Und Wartung

Melody line
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 78
sk tecnica mimì-norma multilingue2.qxp
Hopper capacity
Approx. overall efficiency
Approx. water efficiency
Rated power
Water heating power
Reduced power
Reduced water heating power
Min./max. autonomy
Fuel consumption min./max.
Minimum draught
Max. pressure
Operating pressure
Smoke output temperature from test EN14785
Mass flow
CO emission (13% O2)
Weight including packing (Mimi – Norma)
Heating capacity *
Heating capacity *
* Heating capacity is calculated on the basis of pellets being used, as described in the note regarding fuel, and
house insulation as per Law No. 10/91. A LOT DEPENDS ON THE EFFICIENCY OF THE SYSTEM
TERMINALS (heaters).
Power supply
On/off switch
Average power consumed
Average power consumed upon ignition
Remote control frequency
Main power supply protection
Electronic control board protection
The DEALER can install an optional extra on the AUX port (clean contact, no potential) on the back part of the stove,
to control ignition and shutdown (e.g. telephone combiner, room thermostat).
This can be connected by means of the optional support stand (code 621240).
** placed at the electrical power lead input, with a spare fuse.
CONTROL BOARD
1
AUX
PANNELLO COMANDI
2
SERVICE
Lithium
+
CR2032
MOT ESP FUMI
COCLEA
9
CIRCOLATORE
MANDATA
13
30/11/2009
12.02

SPECIFICATIONS

TECHNICAL AND HEATING SPECIFICATIONS
CARATTERISTICHE ELETTRICHE
SENSORE
FLUSSO
4
5
RPM FUMI
3
6
SONDA ACQUA MANDATA
SONDA ACQUA BOILER
OPZIONALE
7
8
RETE 230Vac
50Hz +/-10%
10
11
FUSE 2A
12
PRESA RETRO STUFA
15
CIRCOLATORE
BOILER
OPZIONALE
14
Pagina 24
8,5 / 26
1-1,5
333 - 299
** Fuse 2A, 250 VAC 5x20
** Fuse 2A, 250 VAC 5x20
OPTIONAL EXTRAS
GSM TELEPHONE COMBINER (code 281900)
for pellet stoves, to ignite/shutdown from a
distance via SMS.
CABLE STAND to connect the Aux port (code
621240)
KEY
Aux Port
1
Control panel
2
3
RPM smoke
Flow sensor
4
Smoke thermocouple
5
6
Water inlet sensor
Optional boiler water sensor (code 633440)
7
Mains 230 V AC, 2nd fuse
8
9
Smoke expulsion motor
TMSR 90°C
10
11
TM 150°C
12
Feed Screw
Supply circulator
13
14
Optional boiler circulator
15
Ignition resistance
23
26
kg
89,9
%
80
%
14
kW
10
kW
5
kW
3
kW
hores
1 / 3
kg/h
12
Pa
2,5
bar
bar
193
°C
9,0
g/s
133
ppm
kg
340
m
3
8
cm
230V
10% 50 Hz
ac +/-
yes
120
W
400
W
infrared

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Norma

Inhaltsverzeichnis