Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Specifications; Safety Devices; Safety Thermostat - EdilKamin Seven Installation, Betrieb Und Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 50
sk tecnica SEVEN multilingua_provvisoria cod 644310.qxp
Nominal power
Efficiency nominal power
Emissions CO (13% O2) nominal power
Smoke mass nominal power
Reduced power
Efficiency reduced power
Emissions CO (13% O2) reduced power
Smoke mass reduced power
Maximum overheated smoke
Minimum draught
Time between refuellings (min/max)
Fuel consumption (min/max)
Hopper capacity
Heatable room dimensions *
Weight including packaging
Smoke duct diameter (A male)
Air intake duct diameter (B male)
* The heatable room dimensions are calculated on the basis of pellets with a lhv of at least 4300 kcal/kg and home insulation
in compliance with Italian law 10/91, and subsequent changes together with an expected heat output of 35 Kcal/m³ per hour. It
is also important to consider the location of the stove in the room to be heated.
N.B.
1) Bear in mind that external devices may cause interference.
2) Caution: live parts. Servicing and/or inspections must be carried out by qualified staff.
(Before carrying out any maintenance, disconnect the device from the mains power supply)

ELECTRICAL SPECIFICATIONS

Power supply
0/1 switch
Average power consumption
Power consumption during
ignition
Remote control frequency
(optional)
Protection on mains power
supply *
Electronic circuit board
protection

SAFETY DEVICES

THERMOCOUPLE: on the smoke outlet.
It measures the smoke temperature.
It controls the ignition, operating and shutdown
stages according to the parameters set.
AIR FLOW SENSOR: on the intake duct. It trips
when the flow of combustion air is not correct,
therefore causing low pressure problems in the
smoke circuit.

SAFETY THERMOSTAT:

It trips if the temperature inside the stove is too
high. It stops pellet loading, thus causing the stove
to go out.
HEATING SPECIFICATIONS
230V
10% 50 Hz
ac +/-
yes
150
W
400
W
infrared
2A, 250 V
5x20
ac
Fuse
2A, 250 V
5x20
ac
Fuse
FUSE
* two fuses are inserted on
the socket behind the stove,
fitted with a switch one is
functional and the other is
* *
spare.
27/04/2010
16.34
Pagina 17
7,0
kW
90
%
100
ppm
5,5
g/s
2,1
kW
92,3
%
280
ppm
2,9
g/s
150
°C
Ø 40 mm
12
Pa
8,5 / 25
hours
0,6 / 1,7
kg/h
15
kg
170
m
3
145
kg
80
mm
40
mm
SMOKE SPEED
ROOM
SENSOR
BACKUP
BATTERY
FLOW
SENSOR
SCREW FEEDER
SMOKE EXTRACTION
MOTOR
SERIAL PORT
The Dealer can install an optio-
nal on the AUX outlet (clean
contact on the pins) for control-
ling the process of switching on
and off (e.g. telephone remote, local thermostat), located
at the rear oh the stove. Can be connected via special
optional trestle (code 620550).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR
2032 battery). Its malfunction is indicated with the follo-
wing messages: (not considered a defect but due to nor-
mal wear-and-tear): ERR 1 - ERR 2. For more detailed
information, please contact the DEALER who has perfor-
med the first 1st ignition.
16
A
B
Ø 80 mm
106 mm
77 mm
457 mm
THERMOCOUPLE
P/TEMP.
VENTILATION
ADJUSTMENT
ADJUSTMENT
230 V AC MAINS
MOTOR
50 Hz +/- 10%
VENTILATION
IGNITION
HEATING ELEMENT
SAFETY
THERMOSTAT
2A FUSE
pin 6
pin 7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis