7.3 Residual water drainage
1. Switch off the appliance and disconnect it from the mains.
2. Remove the cover panel of the drain pump filter; s. chapter 7.2 C
R
EMOVING OF THE DRAIN PUMP FILTER
3. Place a container in front of the opening.
4. Open the drain pump filter, but do not remove it completely. Rotate the drain
pump filter in anti-clockwise direction until the water begins to run.
5. Wait until the water has drained completely.
6. Unscrew the drain pump filter completely and remove it.
7. Carefully tilt the appliance forward so the water can be drained.
8. Insert the drain pump filter and screw it in as far as possible in clockwise direction.
9. Check that the drain pump filter is installed properly.
10. Reinstall the cover panel properly.
WARNING! Ensure before residual water drainage that the water has
cooled down completely. RISK OF SCALDING! RISK OF BURNS!
7.4 Cleaning of the water inlet valve
The water inlet valve should be cleaned at least once every six months.
The water inlet valve must be cleaned, when it is not or improperly supplied with
water with the tap opened.
1. Close the water tap.
2. Disconnect the appliance from the mains (unplug).
3. Remove the water inlet hose from the tap.
4. Clean the internal filter and reconnect the water inlet hose to the tap.
5. Remove the water inlet hose (A) from the water inlet valve (B / water inlet valve
on the back of the appliance): s. fig. below.
6. Remove the filter (D) from the water valve (B) using a universal pliers (C): s. fig.
below.
7. Clean the filter (D) using some water and a toothbrush (E): s. fig. below.
Fig. similar: fig. serve as an example only.
~