Herunterladen Inhalt Inhalt Diese Seite drucken

Husqvarna AUTOMOWER 305 Bedienungsanweisung Seite 13

Vorschau ausblenden Andere Handbücher für AUTOMOWER 305:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

WARNING:
Install only to an residual-current device
(RCD) with a tripping current of maximum
30 mA when connecting the power supply to
the power outlet. Applicable to USA/Canada.
If power supply is installed outdoors: Risk
of Electric Shock. Install only to a covered
Class A GFCI receptacle (residual-current
device) that has an enclosure that is
weatherproof with the attachment plug cap
inserted or removed.
CAUTION:
Do not make new holes in
the charging station plate.
CAUTION:
Do not put your feet on the
baseplate of the charging station.
WARNING:
and the extension cable must be outside the
work area to avoid damage to the cables.
When connecting the power supply, only use a power
outlet that is connected to an residual-current (RCD)
device.
1.
Read and understand the instructions about the
charging station. Refer to
the charging station on page 10 .
2.
Put the charging station in the selected area.
Note:
Do not attach the charging station to the
ground with the screws until the guide wire is
To install the guide wire on page
installed. Refer to
14 .
3.
Connect the low-voltage cable to the charging
station.
4.
Put the power supply at a minimum height of 30
cm / 12 in.
min 30 cm / 12"
5.
Connect the power supply cable to a 100-240V
power outlet.
1508 - 011 -
Risk of Electric Shock.
The power supply cable
To examine where to put
Note:
When the charging station is connected,
it is possible to charge the product. Place the
product in the charging station while the boundary
and guide wires are being laid. Switch on the
product. Do not continue with any product settings
before the installation is complete.
6.
Put the low-voltage cable in the ground with stakes
or bury the cable. Refer to
position with stakes on page 14 or To bury the
boundary wire or the guide wire on page 14 .
7.
Connect the wires to the charging station after
the installation of boundary wire and guide wire is
To install the boundary wire on
complete. Refer to
page 13 and To install the guide wire on page
14 .
8.
Attach the charging station to the ground with the
supplied screws after the guide wire is installed.
To install the guide wire on page 14 .
Refer to
3.5.3 To install the boundary wire
CAUTION:
Do not put remaining wire in
a coil. The coil causes interference with the
product.
1.
Put the boundary wire around all of the work
area. Start and complete the installation behind the
charging station.
2.
Open the connector and put the boundary wire in
the connector.
3.
Close the connector with a pair of pliers.
4.
Cut the boundary wire 1-2 cm / 0.4-0.8 in. above
each connector.
5.
Push the right connector onto the metal pin on the
charging station with the mark "AR".
6.
Push the left connector onto the metal pin on the
charging station with the mark "AL".
To put the wire into
Installation - 13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis