6 Putting into operation

6.3 Mounting the oscillator

In order to mount the oscillator, the torch mount, incl. the fastening plate, must first be disassembled.
Fig. 7
Fig. 8
A 4× mounting screws M5 × 10
B Mounting plate
C Oscillator connection bush
D Adaptor
E 2× mounting screws M5 × 20
A
The oscillator can be mounted either vertically or horizontally.
Screw the fastening plate (B) of the oscillator onto the device.
1
Using the adaptor (D), screw the oscillator (G) onto the fastening plate (B).
2
Attach the welding torch mount (I) with the stop levers (H) to the oscillator.
3
Insert the oscillator's connection cable in the connecting socket (C) and screw it in.
4
Attach the welding torch in the welding torch mount and align.
5
 6.2 Mounting the welding torch on page EN-15
EN - 16
Disassembling the torch mount
Mounting the oscillator
B
C
D
E
F 2× mounting screws M5 × 16
G Oscillator
H Stop lever
I Welding torch mount
F
G
ABICAR 1200 PRO 42V
H
I