Error/malfunction
Not cool enough
Noise development or vibra-
tion
Gurgling noise
Shut-off in heating mode
[E0]-Code
[E1]-Code
[E2]-Code
[E3]-Code
[E4]-Code
If you cannot remedy the fault yourself,
please contact a dealer near you. Please
note that incorrect repairs will invalidate the
warranty and may also cause additional
costs.
30280289, 30288991
Cause
The windows and door in the
room are not closed.
There are heat sources in
the room.
Exhaust air line is not con-
nected or is blocked.
The temperature is set too
high.
Air filter is blocked with dust. Clean the air filter.
The ground is not even or flat
enough.
The noise is created when
the coolant flows inside the
air conditioning device.
Automatic overheating pro-
tection. If the temperature at
the air outlet exceeds 70 °C,
the device switches off.
Room temperature sensor
failed?
Temperature sensor of the
condenser failed?
Condensation tank full dur-
ing cooling?
Condenser temperature
sensor failed?
Condensation tank full dur-
ing heating?
Suomi
Remedy
Ensure that all windows and
doors are closed.
If possible, remove all heat
sources.
Close the line and ensure it
works flawlessly.
Reduce the set temperature.
If possible, place the device
on a flat, even surface.
This is normal.
Switch the device on again,
once it has cooled down.
Replace the room tempera-
ture sensor. (The device will
also function even without
replacement.)
Replace the temperature
sensor of the condenser.
Empty water tank.
Replace the condenser tem-
perature sensor.
Empty water tank.
GB