Herunterladen Inhalt Inhalt Diese Seite drucken

How To Use; Temperature Setting; Venting After Maintenance Work; Cleaning And Maintenance - clage DCX Next serie Kurzanleitung

E-komfortdurchlauferhitzer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DCX Next / DCX 13 Next

3. How to use

Five coloured LEDs

Temperature setting

The temperature selection key
peratures, that are typical for hot water applications: "Hand wash" 35 °C, "Shower"
38 °C, "Bath tub" 42 °C, "Kitchen" 48 °C and "Cleaning" 55 °C.
Every key press sets the temperature to the next level:
35 °C
38 °C
42 °C
Pressing the key
once again, starts the cycle all over.
The currently selected temperature is indicated by one of five coloured LEDs.
For further informations please use the online operation and installa-
tion instruction. Please follow the link below or use the QR code via
smartphone or tablet.
https://www.clage.de/links/gma/DCX-Next-GMA-9120-34381

Venting after maintenance work

This instantaneous water heater features an automatic air bubble protection to prevent
it from inadvertently running dry. Nevertheless, the appliance must be vented before
using it for the first time. Each time the appliance is emptied (e.g. after work on the
plumbing system, if there is a risk of frost or following repair work), the appliance must
be re-vented before it is used again.
1. Disconnect the instantaneous water heater from the mains (e.g. via deactivating the
fuses).
2. Unscrew the jet regulator on the outlet fitting and open the cold water tap valve to
rinse out the water pipe and avoid contaminating the appliance or the jet regulator.
3. Open and close the hot water tap until no more air emerges from the pipe and all
air has been eliminated from the water heater.
4. Only then should you re-connect the power supply again (e.g. via activating the
fuses) to the instantaneous water heater and screw the jet regulator back in.
5. The appliance activates the heater after approx. 10 seconds of continuous water
flow.

Cleaning and maintenance

• Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use
abrasive or chlorine-based cleaning agents or solvents.
• For a good water supply, the outlet fittings (special tap aerators and shower heads)
should be unscrewed and cleaned at regular intervals. Every three years, the electri-
cal and plumbing components should be inspected by an authorised professional in
order to ensure proper functioning and operational safety at all times.
14
allows you to quickly select one of five preset tem-
48 °C
55 °C
Temperature selection
key