TECHNICAL DATA

Power supply unit operating voltage
Rated power
Standby power
Torque
Max. speed
Max. tensile force / initial tensile
force
Short-time operation
Enclosure rating
Protection class
Automatic solar control setting range
Dimensions
Permissible belt widths
Belt length
Max. shutter surface area
Notes:
The specifications provided are recommended values and apply to ideal installa-
tion situations. Due to existing site conditions, the values may be different.
Only use the product with roller shutter belts with the dimensions indicated in the
„Technical data" table� Wrong shutter belt lengths and widths will result in dama-
ge� Replace the old shutter belt when the requirements are not met�
Caution: regularly check the paneling as well as the belt for their flawless con-
dition� In case of risk, decommission the system and have repairs executed by a
specialist�
Note: since the belt pulley in the roller shutter box loses its rigidity due to aging, we
recommend checking and if necessary replacing it after a prolonged usage time�
If the maximum motor run time is exceeded by 4 minutes, the LED clock will flash
quickly and the motor will stop� After approx� 60 minutes, the motor will have its
full operational readiness again�
230 V / 50 Hz
70 W
1 W
8 Nm
36 rpm
30 kg
4 minutes
IP 20 (for dry rooms only)
II
2.000 bis 20.000 Lux
see page 200
23 mm (maxi belt) and
14 mm (mini-belt)
Maxi: 4,0 m bei 1,3 mm Gurtstärke
5,0 m bei 1,0 mm Gurtstärke
Mini: 4,0 m bei 1,3 mm Gurtstärke
5,0 m² plastic
2,5 m² aluminium