Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance Plan - Kärcher SB OB Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SB OB:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
WSO: Only carry out on systems with base exchanger
RO: Only carry out on systems with reverse osmosis.
Time & date
Activity
Daily
Check the high-pressure hoses.
Check the washing brush.
Check the information notices at the wash-
ing station.
Check the leak-tightness of the system.
Check the detergent filling level.
Emptying the coin box
For systems with frost
Check the frost protection devices.
protection: Daily in the
case of frost
Clean the sieve.
Clean the frost protection pump filter.
After 40 operating
Check the oil level of the high-pressure
hours or weekly
pump.
Check the oil level.
Clean the tool holders.
Checking detergent filter
Check for correction function
WSO: Checking the salt tank
WSO: Check the residual hardness of the
softened water
Cleaning the outside of the housing
Cleaning the splash guard tarpaulins
Once, 1 month after
WSO: Changing the WSO ultra-fine filter
initial startup
After 80 operating
Clean and care for the housing.
hours or fortnightly
After 160 operating
Checking the frost protection water quanti-
hours or monthly
ty.
Clean the detergent filters in the detergent
containers.
WSO: Checking the salt tank
Lubricate the door hinges.
Lubricate the locks for doors and control
cabinet doors.
Quarter-yearly
Cleaning the coin slot
After 250 operating
Check the pump head.
hours or half-yearly
Check the fresh water float valves.
Check the pump hose in the dosing pump. Check the pump hose for cracks and wear and replace if necessary.
After 500 operating
Completely check the high-pressure
hours or annually
pumps.
Replace the oil in the high-pressure pump. See Maintenance work.
Annually before the
Cleaning the filter in the Power foam noz-
frost period
zle (option)
Every 1000 operating
WSO: Changing the WSO ultra-fine filter
hours
Safety check
26

Maintenance plan

Performed
Examine the high-pressure hoses for mechanical damage such as abrasion damage,
visible hose fabric, kinks and cracked rubber. Replace damage high-pressure hoses.
Check the washing brushes for damage, soiling and wear. Replace bristles that are
shorter than 30 mm. In winter at temperatures below –5 °C, check for ice formation
and lock the foam wash if necessary. Replace the combination spray lance with a high-
pressure spray lance for this
Check that the user information notices are present and legible.
Check pump and line system for leaks. Contact Customer Service when oil is present
under the high-pressure pump or when more than 3 drops of water per minute escape
from the high-pressure pump during operation.
Check the filling level and refill if necessary.
Open the appliance door and empty the coin box.
Is the hot air fan operating?
Is the setting of the thermostat regulator correct (warmer than -10 °C - level "I", colder
than -10 °C - level "II")?
Is the frost protection device operating (frost protection water quantity of approx. 0.5 l/min)?
Is the tool holder drain opening free?
See the section "Cleaning the sieve".
Clean the filter and re-insert.
The oil level must lie between the MIN and MAX marks, otherwise refill with oil.
Milky oil indicates water in the oil. Notify Customer Service.
Remove dirt from the tool holders.
Visually check the high-pressure jet for the presence of detergent, clean detergent fil-
ter if necessary.
Checking the functionality of all washing programs
Is the salt level above the water level? Top up the softening salt if necessary.
Remove water from the hot water float tank and determine the residual hardness with
test set B (order no. 6.768-003). Target value: Less than 3 °dH.
Mix a 10% solution of the "Washing hall and tile cleaner RM 841" detergent, apply to
the surfaces, allow to react for approx. 2 to 3 minutes, do not allow to dry. After the
contact time, rinse thoroughly with the high-pressure jet.
Mix a 20 % solution of "Washing Hall and Tile Cleaner RM 841" detergent, apply to the
surface and allow to react for approx. 2 to 3 minutes. After the contact time, clean the
surfaces with a damp pad or microfibre cloth and then rinse thoroughly with a high-
pressure jet. If desired, the large surfaces can be wiped off with a rubber squeegee.
Mix a 10% solution of the "Washing hall and tile cleaner RM 841" detergent, apply to
the surfaces, allow to react for approx. 2 to 3 minutes, do not allow to dry. After the
contact time, rinse thoroughly with the high-pressure jet.
ATTENTION
Risk of damage
Solvents and detergents containing solvents can damage the splash guard tarpaulins.
Do not clean the splash guard tarpaulins with solvents or detergents containing solvents.
Shut off the fresh water inlet, unscrew the filter cup, replace the filter insert, refit the
new filter insert and filter cup, open the fresh water inlet.
Thoroughly clean the exterior and interior of the housing.
Minimum value: approx. 0.5 l/min per washing tool (the tool with the lowest flow is de-
cisive).
Water quantity smaller with frost protection circuit: Clean the frost protection
pump filter, clean the sieve (on the frost protection ball tap), flush the line.
Larger water quantity for all tools: Regulate the water quantity with the frost protec-
tion ball tap.
Larger water quantity only at the high-pressure gun: Replace the node piece in
the high-pressure gun.
WARNING
The high-pressure gun can move uncontrollably and cause injuries if the frost
protection water quantity is too high.
Be sure to replace the node piece in the high-pressure gun if the frost protection water
quantity is too high.
Remove the filter and rinse thoroughly with clean water.
Check the water level (approx. 5...25 cm above the sieve plate).
Check for deposits, empty if necessary, clean, refill with softening salt and put back
into operation. Danger of malfunctions. When topping up with softening salt, use only
the softening salt in tablet form listed in the chapter 'Accessories'.
Lubricate the hinges with grease (order no.: 6.288-072).
Spray care agent (order no.: 6.288-116) into the locks.
Open the device door. Clean the coin slot (see section "Maintenance work").
If water escapes from the overflow hose, check the seal at the float valve. If necessary,
replace the float valve.
See "Cleaning the frost protection/Power foam nozzle". Determine the following clean-
ing intervals according to experience.
Shut off the fresh water inlet, unscrew the filter cup, replace the filter insert, refit the
new filter insert and filter cup, open the fresh water inlet.
Safety check according to the directives for liquid jet cleaners/accident prevention
guideline.
English
By whom
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Customer Service
Operator/Custom-
er Service
Operator/Custom-
er Service
Customer Service
Operator
Operator
Operator
Customer Service

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis