Herunterladen Inhalt Inhalt Diese Seite drucken

Emergency Information; Product Description; Technical Data; Figures Used - Abicor Binzel RAB GRIP Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5

3 Product description

2.9

Emergency information

► In the event of an emergency, immediately disconnect the following
supplies: electrical power supply, compressed air supply, coolant supply
and shielding gas supply.
3
Product description
3.1

Technical data

Tab. 1
General torch data (EN 60974-7)
Temperature
(transport and storage)
Temperature (operation)
Relative humidity
Type of use
Type of voltage
Polarity of the wire electrode for DC Usually positive
Tab. 2
Product-specific torch data (EN 60974-7 and EN ISO 21904-1) (For induced speed 0.25 m/s)
Type
Type of
RAB GRIP
cooling
Load
CO
M21
2
A
A
15AK
Air
180
150
25AK
Air
230
200
155
Air
160
140
255
Air
250
200
1When used with welding fume extraction systems of the RAB GRIP series.
Tab. 3
Product-specific torch data (EN 60974-7 and EN ISO 21904-1) (For induced speed 0.35 m/s)
Type
Type of
RAB GRIP
cooling
Load
CO
M21
2
A
A
24KD
Air
250
220
36KD
Air
300
270
240D
Liquid
300
270
501D
Liquid
500
450
355
Air
360
320
24HE
Air
250
220
36HE
Air
300
270
501HE
Liquid
500
450
1When used with welding fume extraction systems of the RAB GRIP series.
The volume the torch-integrated extraction system collects depends on many
factors, such as the position of the suction nozzle, the welding geometry and
the gas emission rate of the welding process.
Tab. 4
Liquid cooling/cable assembly specifications
Cooling data
Supply temp.
Max. 40 °C
Flow
Min. 1.5 L/min
Flow pressure
Min. 2.5 bar/max. 3.5 bar
Coolant connection
Plug-in nipple with DN 5
Cooling device output
Min. 800 W
3.2

Figures used

All figures can be found at the start of this document.
EN - 32
−25 °C to +55 °C
−10°C to +40°C
Up to 90% at 20 °C
Hand-held
DC
DC
Wire Ø
Gas flow rate
%
mm
L/min
60
0.6–1.0
10–18
60
0.8–1.2
10–18
60
0.6–1.0
10–18
60
0.8–1.2
10–18
DC
Wire Ø
Gas flow rate
%
mm
L/min
60
0.8–1.2
10–18
60
0.8–1.2
10–20
100
0.8–1.2
10–20
100
1.0–1.6
10–20
60
1.0–1.6
10–20
60
0.8–1.2
10–18
60
0.8–1.2
10–20
100
1.0–1.6
10–20
► Consult the documentation for welding components.
Shielding gas (DIN EN ISO 14175)
Wire types
Voltage rating
Protection type of the device
connections (EN 60529)
Control features in the handle
1
Volume flow
For induced speed 0.25 m/s
Suction nozzle
Connector
3
3
m
/h
m
/h
37.4
59.5
40
58.7
28.3
40.5
41
68.5
1
Volume flow
For induced speed 0.35 m/s
Suction nozzle
Connector
3
3
m
/h
m
/h
52.3
81.5
44.5
81.1
49.6
77.9
45.3
80
52.3
89.4
49.6
99
72.1
120
71.7
122
Under optimal conditions, over 95% of the welding fumes can be captured
in accordance with ISO 21904-3.
Cable assembly
Standard length L
Control lead
RAB GRIP
CO
and mixed gases M21
2
Commercially available round
wires
Peak value of 113 V
IP3X
For 42 V and 0.1–1 A
Required vacuum at the
connector
kPa
5.7
5.9
3.2
8.5
Required vacuum at the
connector
kPa
10.9
8.4
8.1
12.3
13.8
7.6
11.2
13.7
4.00 m, 5.00 m
2-lead

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis