10 Faults and troubleshooting

Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with forced ventilation.
► Ensure that all seals on the device are free from dirt and debris.
► The provided filtration system must be used when operating the device.
► The dust collecting drawer must be closed when operating the device.
► Do not open the dust collecting drawer until at least one minute has passed since the device was
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
► Observe the documentation for the welding components.
► Observe the "Warranty" documentation.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Tab. 3
Fault
Extraction volume too low.
Device is not ready for
operation.
WARNING
switched off.
or a damp cloth.
Faults and troubleshooting
10 Faults and troubleshooting
Cause
Filter cartridge contaminated/
defective.
Reduction of the cross-section of
the extraction hose.
Extraction system defective.
Extraction system is not mounted
concentrically to the ventilation
grille of the cover plate.
Device cannot be switched on/
motor protective switch tripped.
Troubleshooting
► Clean the filter.
 9.2 Cleaning the filter on
page EN-16
► Empty the filter housing.
 9.3 Emptying the filter
housing on page EN-17
► Replace the filter.
 9.4 Replacing the filter on
page EN-18
► Replace the extraction hose.
 6.3 Connecting the
separate exhaust air hose
(optional) on page EN-13
► Have the extraction system
replaced by a qualified
electrician.
► Have the position of the
extraction system corrected by
a qualified electrician and
have it remounted if necessary.
► Allow the device to cool down
and press the motor protective
switch back in.
 Fig. 4 Control elements and
connections on
page EN-10
► Have carbon brushes checked
for wear by a qualified
electrician, replace if
necessary and press motor
protective switch back in.