9 Maintenance and cleaning

9.8 Replacing the cleaning lance

EN - 24
Tilt the housing forward and remove the filter
1
cartridge.
 9.4.1 Replacing filter cartridges on page EN-18
Pull the cleaning lance out of the filter housing as far
2
as it will go on the top of the device.
Loosen the threaded fitting on the tube with a
3
combination wrench (AF18 and 22) and remove the
ball valve, nipple and threaded fitting.
Remove the cleaning lance from the bottom of the
4
tilted filter housing.
Insert the new cleaning lance from below into the filter
5
housing and pull the cleaning lance out of the filter
housing as far as it will go on the top of the device.
Loosen the threaded fitting on the tube with
6
a combination wrench (AF18 and 22) and mount the
ball valve, nipple and threaded fitting.
Insert and fasten the filter cartridge and close the
7
housing.
 9.4.1 Replacing filter cartridges on page EN-18