Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel FEC Originalbetriebsanleitung Seite 46

Hochvakuum rauchgas-absauggerät
Vorschau ausblenden Andere Handbücher für FEC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9 Maintenance and cleaning
Electric shock due to defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
9.1 Maintenance and cleaning intervals
Authorized personnel must clean and inspect the device regularly. Any dirty device components that cannot
be cleaned adequately must be replaced. The dirty components must be placed in bags that are
impermeable (so dust cannot escape) and disposed of in accordance with regulatory stipulations. The
specified intervals are standard values and refer to single-shift operation. We recommend recording the
inspections. The date of the inspection, the detected defects and the name of the inspector must be observed.
Daily
Monthly
Yearly
EN - 16
WARNING
CAUTION
► Check the device, filter housing, cable connections, and seals for
visible damage.
► Empty the filter housing.
 9.3 Emptying the filter housing on page EN-17
► Check the filter cartridge for leaks or contamination.
► Check the exhaust air filter for leaks and contamination and replace
if necessary.
 9.4.2 Replacing the exhaust air filter on page EN-20
► Check the filter pad for leakage or contamination and replace if
necessary.
 9.5 Replacing the filter pad on page EN-21
► Carbon brushes must be checked and replaced as needed only by a
qualified electrician.
► Turbines must be checked, cleaned and replaced as needed only by
a qualified electrician.
► Replace the exhaust air filter.
 9.4.2 Replacing the exhaust air filter on page EN-20