FEC

9.2 Cleaning the filter

NOTICE
Risk of material damage due to improper filter cleaning
Improper filter cleaning can damage the filter elements. The result may be insufficient extraction.
► Use only dry and oil-free compressed air (min. 5 – max. 6.5 bar).
► The filter should be cleaned at least once per work shift, depending on how often the system is used.
► Clean the filter immediately when the <Dirty> LED lights up on the control panel.
9 Maintenance and cleaning
Connect the compressed air supply.
1
Open the valve lever on the compressed air
2
connection.
The compressed air creates a dedusting jet and causes
the dedusting nozzle to rotate inside the filter cartridge.
Manually move the cleaning lance up and down
3
multiple times. The filter cartridge is cleaned by
manually moving the cleaning lance up and down.
Close the valve lever on the compressed air
4
connection.
EN - 17