Setting up the docking station outside the mow‐
ing area
a
The docking station is outside the mowing area.
The minimum lateral distance toward adjacent
areas must be at least a = 15 cm.
The minimum distance between the front edge of
the docking station and the mowing area must be
at least b = 2 m.
With this variant, it is mandatory to define a start‐
ing point (1) within the mowing area at the con‐
clusion of commissioning. The robot mower then
starts mowing from this point and not directly
from the docking station. Starting points can be
set with the MYiMOW® app. The approach fre‐
quency of the starting point (1) must be set in the
app at 100%.
► Preparing the docking station,
► Setting up the docking station outside the
mowing area,
7.5.
Setting up the docking station in the center of the
mowing area
b
a
The docking station is positioned as an island in
the center of the mowing area.
62
a
b
1
7.3.
a
7 Positioning the docking station
With this variant, the perimeter wire is routed
around the docking station toward the rear and
the edge of the mowing area. The guide wire is
routed toward the front to the edge of the mow‐
ing area.
The minimum lateral distance to adjacent areas
must be at least a = 37 cm (length: 1x iMOW
Ruler).
The minimum distance between the rear edge of
the docking station and the edge of the mowing
area must be b = 2 m.
► Preparing the docking station,
► Setting up the docking station in the center of
the mowing area,
7.3
Preparing the docking station
Connecting the charging cable.
NOTICE
■ In assembled condition, the plug connections
of the charging cable are protected against
contamination, e.g. dust and dirt. Contamina‐
tion of the plug connections may result in
breakdowns of the docking station.
► Protect open plug connections against con‐
tamination.
► Clean the contaminated plug connections
as described in this User Manual.
Normally the charging cable is connected from
the rear.
If the docking station has been positioned
directly against a wall, it is also possible to install
the charging cable under the base plate. The
7.3.