Herunterladen Inhalt Inhalt Diese Seite drucken

Switch-On Timer Setting From The Remote Control; Switch-Off Timer Setting From The Remote Control; Setting Combined Timer (Simultaneous Setting Of The On And Off Timers) - Olimpia splendid NEXYA S4 E INVERTER 9 Hinweise Für Die Verwendung Und Pflege

Vorschau ausblenden Andere Handbücher für NEXYA S4 E INVERTER 9:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 67
c. Once the time has been set for TIMER ON and TIMER OFF, check that the TIMER indicator on the indoor
unit display is on.
MODIFICATIONS
• Repeat phases "a", "b" and "c" to change the settings.
3.7.1 - Switch-on timer setting from the remote control (figures 27, 28 and 31)
When the unit has been switched on, select the operational mode, the desired temperature and fan speed
with which the unit will activate on scheduled switch-on.
Successively put the machine in Stand-By.
Press the "TIMER ON" key (7) to set the desired delay (from 1 to 24 hours), after which the unit will switch
on (starting from confirmation of the timer).
If no key is pressed within 5 seconds, the timer setting function ends automatically.
The remote control displays the countdown until switch-on.
Once the time set has expired, the unit starts with the last settings selected.
3.7.2 - Switch-off timer setting from the remote control (figures 27, 28 and 32)
With the unit in any operational mode, press the "TIMER OFF" key (8) to set the desired delay (from 1 to 24
hours), after which the unit will switch off (starting from confirmation of the timer).
If no key is pressed within 5 seconds, the timer setting function ends automatically.
The remote control displays the countdown until switch-off.
Once the time set has passed, the unit switches off.

3.7.3 - Setting combined timer (Simultaneous setting of the ON and OFF timers)

TIMER OFF > TIMER ON (figures 27, 28 and 33)
(On => Stop => Start functioning)
This function is useful if the air conditioner is to be switched off after going to bed and switched back on in
the morning or when returning home.
Example:
The time is 20:00. If the air conditioner is to be switched off at 23:00 and switched back on at 06:00.
a. Press the "TIMER OFF" key (8) to display "TIMER OFF".
the time flashes.
b. Press the "TEMP" keys (4) until the value "3:00" is set near to the "TIMER OFF" indicator.
c. Press the "TIMER ON" key (7) to display "TIMER ON".
the time flashes.
d. Press the "TEMP" keys (4) until the value "10:00" is set near to the "TIMER ON" indicator.
e. Wait 3 seconds, the time set will stop flashing and the function will be active.
TIMER ON > TIMER OFF (figures "27", "28" and "34")
(On => Stop => Start functioning)
This function is useful if the air conditioner is to be switched on before getting up and switched off after
leaving home.
Example:
The time is 20:00. If the air conditioner is to be switched on at 06:00 the next morning and switched of at 08:00.
a. Press the "TIMER ON" key (7) to display "TIMER ON".
the time flashes.
b. Press the "TEMP" keys (4) until the value "10:00" is set near to the "TIMER ON" indicator.
c. Press the "TIMER OFF" key (8) to display "TIMER OFF".
the time flashes.
d. Press the "TEMP" keys (4) until the value "12:00" is set near to the "TIMER OFF" indicator.
e. Wait 3 seconds, the time set will stop flashing and the function will be active.
EN - 16

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis