Indicator
Meaning
Rechargeable battery is not inserted.
Status LED is red.
Malfunction
(see chapter 4 Troubleshooting)
Status LED is flash-
ing red.
When the rechargeable battery is fully charged, the charger
switches automatically to standby. In standby mode, the
rechargeable battery stays fully charged at all times. In this
mode the rechargeable battery is neither overcharged nor
damaged.
2.3

Feature description

The powered air purifying respirator is a respiratory protective
device depending on circulating air. It filters the ambient air
and makes it available as breathable air. The device
continuously takes in ambient air through the filter. The filter
absorbs harmful substances depending on the filter type. In
this way, the ambient air is recycled and finally reaches the
facepiece. There it is available as breathable air.
A continuous overpressure in the facepiece prevents ambient
air from penetrating.
2.4

Limitations on use

The device is not suitable for use:
– when there is a suspicion of contaminants with low
warning properties (smell, taste, irritation of eyes and
airways)
– in unventilated tanks, pits, canals etc.
– when there is suspicion of contaminant concentrations
that represent an immediate danger to life or health - IDLH
concentrations
In explosion-hazard areas, the X-plore 8700 fan unit may
not be used with the welding protective visor (component list
pos. 19), the standard hood, long (pos. 10 and 11) and the
hose cover, disposable (pos. 41).
2.5

Intended use

Depending on the employed filter type, the device protects
against particles, gases and vapours or combinations hereof.
Only powered air purifying respirator X-plore 8700 is intended
for use in explosion-hazard areas.
For an overview of the device combinations and the
protection classes, refer to the Configuration Matrix at the end
of these instructions for use.
The numbers in the first line of the Configuration Matrix
correspond to the positions in the component list.
The listed components are intended for use with the X-
plore 8000 fan units (component list pos. 1 and 2) and the
rechargeable batteries (pos. 3 and 6).
Dräger would be happy to answer any questions you may
have regarding device configuration.
Instructions for use
|
Dräger X-plore® 8000
2.6

Approvals

2.6.1 Respiratory protection

The powered air purifying respirator is approved according to
– EN 12941
– EN 12942
– AS/NZS 1716:2012
– (EU) 2016/425
Declaration of conformity see Dräger X-plore 8000 Notes on
approval or www.draeger.com/product-certificates

2.6.2 ATEX and IECEx

The X-plore 8700 powered air purifying respirator is approved
under designation APR 00** according to
– EN/IEC 60079-0
– EN/IEC 60079-11
The device satisfies the ATEX Directive 2014/34/EU.
Name of device according to ATEX
II 2G Ex ib IIB T4 Gb
II 2D Ex ib IIIB T135 °C Db
TA: -10 °C < Ta < +50 °C
Name of device according to IECEx
Ex ib IIB T4 Gb
Ex ib IIIB T135 °C Db
T
: -10 °C < Ta < +50 °C
A
2.7
Explanation of type-identifying
marking and symbols

2.7.1 Name plates

Illustration of the name plates, refer to fold-out page.
Fan unit
Figure H
Rechargeable bat-
Figure I
tery
Standard battery
Figure J
charger
1
Product name
2
International Protection Code
3
Approval marking
4
Symbol "Follow instructions for use"
5
WEEE symbol "Separate collection of electrical and
electronic equipment"
6
Country of production
7
Manufacturer
8
CE marking
9
DataMatrix code with part and serial number
10 Serial number
11 Part number
12 Only for indoor use, not for outdoor use
13 Maximum ambient temperature
|