4.4 Installing the pneumatics

WARNING
Risk of injuries through leaking compressed air
and lashing pneumatic hoses
Open or loose pneumatic connections can cause severe in-
juries.
h Make sure that during installation and service of the
pneumatic hoses and of the service unit compressed air
is not running through the hoses and connections.
h After installing the pneumatic hoses but before running
compressed air through the hoses and connectors, check
if the hoses are securely inserted into the correct connec-
tors and are not damaged.
h Do not run compressed air through damaged hoses and
connectors.
NOTICE
The spindle may suffer bearing damage and
electrical damage if the compressed air is
contaminated
The incoming compressed air must be dry and oil-free ac-
cording to ISO 8573-1 because the service unit only serves as
an indicator for contaminated air.
Air purity according to ISO 8573-1
Solid particles
Class 3
Water content
Class 4
Residual oil content
Class 3
h Ensure that the compressed air meets the above require-
ments.
h Connect the machine to the compressed air supply only
via the provided service unit.
The spindle requires compressed air for the following tasks:
For the opening and closing of the collet chuck during
tool change.
For the sealing air which prevents foreign bodies from
entering the spindle.
Air consumption of the machine:
approx. 50 l/min (1.8 cfm) at 6 bar (90 psi)
approx. 80 l/min (2.8 cfm) at 8 bar (120 psi)

4.4.1 Overview service unit

Via the service unit you connect the Machine to your com-
pressed air supply and regulate the incoming pressure for the
machine.
Fig. 6:
Filtration degree
better than 5 µm
for solid particles
[1] Rotary knob for pressure regulation
[2] Pneumatic connection to the machine (ø 6 mm)
Maximum pressure
[3] Manometer for monitoring the outgoing pressure
dew point +3 °C
[4] Water separator
Maximum oil con-
[5] Discharging screw
tent: 1 mg/m³
[6] Pneumatic connection for external compressed air

4.4.2 Mounting the service unit on the Machine

Failure of the water separator caused by a
wrong alignment of the service unit
The service unit must always be mounted in an upright po-
sition because otherwise the water separator will not work.
h Mount the service unit in an upright position (
On the left side of the Machine are two bores which you can
use to mount the service unit on the machine.
M
Original Operating Instructions: K4 edition
Document version: E – 02/2020
6
The service unit: regulating and checking the air pressure
supply
NOTICE
Mount the service unit in an upright position, using
the lens head screws provided in the bores.
Installing the machine
1
2
3
4
5
Fig. 6).
