Combustion air
Being the user of the stove you must take care of a sufficient
combustion air supply. Sealed-up windows and doors may
not allow a sufficient combustion air supply or disturb the
draught behaviour of your stove. Please ensure the
additional supply of fresh combustion air if necessary. For
details please consult your specialist retailer. Make sure that
the combustion air intakes are not blocked!

3. CORRECT OPERATION OF YOUR STOVE

Approved fuels

Dry, well cured and natural wood (hardwood preferred),
wood briquettes.
Maximum amount of fuel
Maximum amount of fuel to be added: 1,6 kg wood or
briquettes. Larger amounts of fuel can lead to overheating
and thus damage the stove.
Clean burning
The wood must be dry (relative wood moisture < 15%) and
untreated and the right amount of wood must be burned in
order to ensure a clean fire that releases only small amounts
of emissions.

Startup procedures

During the first 3-4 operations - at nominal heat output -
there may be some odour development and the varnish has
not yet hardened.

Making a fire

For the correct and safe operation of your stove please pay
attention of the chimney developing the necessary feed
pressure. This must especially be considered before the
initial operation (or e.g. after the summer heating break)
and during the mid-season heating periods (e.g. at strong
wind, etc.).
If there is not enough feed pressure, please light only some
paper or small kindling first, in order to "warm up" the stove
and the chimney.
The air inlet must not be covered or closed.
Clean grate, empty ash drawer if necessary (watch out for
ambers!)!
Position the lever for the combustion air to the open ("AUF")
position (see fig. 2 and 4).
Place 2-3 logs (approx. 1,1 kg in total) crossways in the
combustion chamber (1) with sufficient distance from each
other (min. 2 cm), on top of that place some softwood
chippings (approx. 0.5 kg) (2) and some ignition aid and
light. (3) (see fig. 3)
Stove pipe connection
For your own safety stringent laws apply for connecting the
stove pipes to the chimney. Your professional dealer or
distributor knows these laws. Please have your certified
retailer carry out the connection of your stove.
3
Figure 3:ignite the fire
Close the door!
We recommend to let the first load burn down without
changing the air lever position.
As soon as no visible flames are left (only embers in the
combustion chamber), you can put another load of logs
(approx. 1,6 kg) in the combustion chamber if desired. (see
fig. 5)
When reloading the stove please repeat the procedure as
mentioned under "first lighting": air lever top position (=
open), open door carefully, place logs, close door.
Fig. 4: air knob
After a few minutes, when the logs burn well on all sides
(bright, high flames), you can adjust the heat output with the
air lever (lever on top position = maximum heat output), the
flames should be yellow and never look blueish or have
black tips (otherwise add more air) – see fig. 4. Never close
air supply completely during operation. (danger of flash-
fire!)
The stove door may be opened only for refuelling or
disposing of ashes and is to be closed again afterwards.