E
TROUBLE SHOOTING
PROBLEMS
• The conditioner does not work.
• The conditioner works only for a
short period.
• The conditioner works but does not
refresh the room.
• Water leaks from the conditioner
during transport.
• Alarm signal " Fi " appears on the control
panel display
• The conditioner switches off, the controls on
the remote control and the control panel do
not respond and alarm signal "2" flashes on
the control panel display.
• The conditioner switches off, the controls on
the remote control and the control panel do
not respond and alarm signal "8" flashes on
the control panel display.
• The conditioner switches off, the controls on
the remote control and the control panel do
not respond and alarm signal "3" flashes on
the control panel display.
• Alarm signal "13" flashes on the control
panel display.
P
LIKELY CAUSE
• No power.
• The plug has not been inserted.
• Timer is ON
• The temperature set is too close to
ambient temperature.
• Suction of outside air is obstructed.
• Window open.
• Some source of heat is operating in the
room (burner, lamps, etc.) or the room
is crowded.
• The temperature set is too high.
• The power of the conditioner is not
suitable for ambient conditions or
dimensions.
• The conditioner has been tilted or laid
flat.
• The filter is dirty
• Excessive build-up of water inside the
conditioner
NL
SUGGESTED SOLUTION
• Wait.
• Plug in the conditioner.
• Switch off the timer
• Lower the temperature set.
• Remove the obstructions.
• Call the Service Center.
• Close the window.
• Eliminate sources of heat.
• Lower the temperature set.
• Remove the plug (fig.2 ref. n°4) and drain
the water before moving the conditioner.
• Clean the filter (refer to section 3.17)
• Switch the appliance back on and press
button SW1 on the control panel for 5
seconds so that the alarm signal disappears
from the display.
• Call the Service Centre.
• Call the Service Centre.
• Dain the water contained by removing the
plug (fig.2 ref. n°4). If this alarm is displayed
too frequently, call the Service Centre.
• Call the Service Centre.
GR