7.3.1 CP 5511 (PROFIBUS - DP Master) Parameter Assignments

"CP 5511
The "CP 5511 (PROFIBUS DP Master)" parameter assignment is
required for the DP master mode. In the "DP Master" dialog, you can
(PROFIBUS - DP
specify whether the DP master is the only active station in the
Master)" Parameter
PROFIBUS network.
Assignments
If you want the PC with SOFTNET DP to be the only master in the
network or to be the first master to become active, the "Programming
device / PC is the only master on the bus" check box must be
activated.
In this dialog, you can also specify a DP database for this device
parameter assignment. For more information about creating the
database, refer to Chapter 8.
For the DP mode, it is essential to specify a DP database.
Specifying the DP
It is not possible to set the bus parameters for DP using the "Set
PG/PC Interface" configuration program. These are specified when you
Bus Parameters
configure with COM PROFIBUS and they are saved in the database.