C79000-Z8974-C70-02CP 5511 Communications Card under Windows 98, NT 4.0, 2000 Professional
10 Troubleshooting
10.1 Windows 98
Card not Entered
The controller type does not match the Card & Socket services with
which Windows 98 operates.
in the Device
Manager?
Resource
You can reassign resources in the Control Panel (double-click the entry
"PCMCIA Card Siemens CP 5511"). Check whether a resource conflict
Problem?
is reported in the device manager.
Wrong PG/PC
Check whether the access point and the interface parameter
assignment match.
Setting?
Make sure that the existing configuration is entered in the PG/PC
Incorrect
Interface. Check the node addresses and the bus parameters settings.
Configuration?
10.2 Windows NT 4.0
Controller Type
Check whether your controller type or platform is supported by the
Cardware version. The information about the controller type is often on
Problem?
the controller itself. If you cannot find the information there, contact the
manufacturer of your computer.
SystemSoft
As an alternative to the Award Cardware, you can also use the
CardWizard from SystemSoft if Cardware cannot be run on your
CardWizard
computer. For more detailed information refer to the "readme.txt" file of
your product and in the instructions for operating the SystemSoft
CardWizard (PDF file on your CD).