Herunterladen Inhalt Inhalt Diese Seite drucken

Transport; Maintenance And Cleaning; Storage; Electrical Connection - Scheppach 5903819901 Original Bedienungsanleitung

Universal-renovierungsschleifer
Vorschau ausblenden Andere Handbücher für 5903819901:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

10. Transport

Always switch off the power tool before transport and
disconnect it from the power supply.
To transport the power tool, lift it by the centre struts.
Protect the electrical tool from impacts, shocks and se-
vere vibrations, e.g. during vehicular transport.
Secure the power tool against toppling and slipping.

11. Maintenance and cleaning

m WARNING!
Pull out the mains plug before carrying out any adjust-
ments, maintenance or repair work!
General maintenance tasks
• Always keep the cooling air openings in the housing
clean and clear for air circulation.
• Rub the device clean with a clean cloth or blow it off
with compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior.
• There are no parts which can be repaired by the
user within the device. Never try to repair the device
yourself. Always contact a qualified specialist.
Replacing the connection cable
If the mains connection cable of the plunge saw is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualified person to
avoid dangers.
Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consuma-
bles.
Wearing parts*: Carbon brushes, brushing roller
* may not be included in the scope of supply!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
28 | GB

12. Storage

Store the device and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The op-
timum storage temperature lies between 5 and 30 ˚C.
Store the power tool in its original packaging.
Cover the electric tool to protect it from dust or mois-
ture.
Store the operating manual with the power tool.

13. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the exten-
sion cable used must also comply with these reg-
ulations.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
www.scheppach.com

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mrs1300

Inhaltsverzeichnis