Herunterladen Inhalt Inhalt Diese Seite drucken

glass 1989 Infinity Bedienungs- & Wartungsanleitung Seite 55

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

point
• Touching the LIGHT key and holding
for ≥ 3s; the display will show the new
temperature set point value alternating
with the message "Eco" for a few
seconds, then revert to the current water
temperature.
• One touch of either the PLUS or the
MINUS key will be sufficient to check
whether or not the function is active. If
the function is active, the display will
show the temperature set point value
alternating with the message "Eco"; if not,
only the set point value will be displayed.
• To deactivate the function: same
procedure as described above; the
display will show the previous value of
the set point.
WATER FILL
Manage of water fill
The system is filled with water in response
to signals from level sensors L1 in the tub
or pool, and L2 in the compensation tank
If L1 = 0 at power-up, the fill solenoid
valve activates automatically and the
message "L1" appears in the display,
alternating with the water temperature,
to indicate the target level.
When level L1 is established, the
continuous fill solenoid valve stays
energized, the message L1 disappears
and the message L2 appears (still
alternating with the temperature value);
in this instance L2 represents a target
level (meaning that the compensation
tank must also be filled). With the level
established, the fill solenoid valve
deactivates after 10 seconds and the
message L2 disappears from the display.
Once the level has been established,
the display reverts to showing the water
temperature only (no alternation with L2).
Power-up with tub/pool empty
In this situation, all of the user loads
are disabled, except for the light.
The fill SV now energizes and a timeout
of 90 minutes is initiated.
If level L1 fails to register within the 90
minutes, the system locks up, the fill
solenoid valve is deactivated and the
message "AL1" is displayed. The alarm
can be reset only by switching off and
rebooting the controller.
If tub/pool correctly filled within the
90 minutes, level L2 must also be
established.
The
fill
solenoid
energized
and
minutes is initiated. If level L2 fails
to register within the 90 minutes, the
fill solenoid valve is deactivated and
the
message
The display of alarms is always alternated
with that of the water temperature.
Special case: if the tub or pool is already
full (L1 = 1) at power-up, the loads will be
enabled straight away.
Tub/pool part-empty (L1=0, L2=1)
In this instance, only the level of the
compensation tank is detected. All user
loads are disabled, except for the light. At
power-up, or after 1 minute has elapsed
in this condition, the controller activates
the fill solenoid valve and initiates a
timeout of 90 minutes.
Once the level is established (L1 = 1),
the fill solenoid valve will be deactivated
and the user loads enabled. Should a
load start up (WHIRLPOOL PUMP or
CIRCULATION PUMP) when level L1 is
established, thereby lowering level L2,
the Fill solenoid valve will be activated
until level L2 is restored.
If the level fails to register within the 90
minutes, the system locks up, the fill
solenoid valve is deactivated and the
message "AL1" is displayed. The alarm
can be reset only by switching off and
rebooting the controller.
Power-up with tub/pool full
(L1=L2=1)
All sensor detect the level as full; user
loads are enable.
ALARMS
15
valve
remains
a
timeout
of
"AL2"
is
displayed.
EN
90