DISPLAY AT POWER-UP
At power-up, all Leds and segments of the
display will light up for 3 seconds, after
which the version and the revision of the
firmware are shown (for 6 seconds).
KEYPAD LOCK ACTIVATION/
DEACTIVATION
It is possible to activate/deactivate the
keypad lock by acting on a combination
of keys regardless of the status of the
user functions.
Press the two central keys of the keyboard
at the same time for at least 3s, regardless
of the status of the user functions
With keyboard lock active by pressing
any key, the display shows "LOC" for 5s
then returns to display the temperature of
the water in the tank.
The active lockout state is stored in non-
volatile memory to prevent a reset from
removing the lockout.
Note: f the lock is activated with an active
user function, it can be switched off only
by timeout .
FILTRATION
The filtration cycle comprises a first stage
in which all loads are activated (creating a
suspension of precipitate in the water), then
a second stage in which the water is filtered
and sanitized by the circulation pump.
Activation of loads during filtration::
First stage: the whirlpool pumps and
blower (if installed) are activated in
sequence for 1 minute each. A pause of 5
seconds inactivity is left between one load
switching off and the next load starting up.
Second stage: when included, ozonator
is activated for the rest of the cycle time.
When filtration is in progress, the message
"FLt" appears in the display, alternating
with the water temperature.
If "SILENCE" mode is active at the
moment when filtration is selected, the
filtration cycle will not take place.
If Smart Winter Mode is activated, filtration
will be suspended, then restarted 1 minute
after SWM finishes.
Filtration is suspended during activation
of a user load, and will resume once 5
minutes have elapsed after the load has
been deactivated.
SMART WINTER MODE (antifreeze)
With this function installed, the loads
are activated periodically to prevent
the plumbing system of the tub or pool
from freezing up. The function starts
automatically if the temperature detected
by the H2O probe is ≤ 7 °C
This function will be activated even when
other functions are inhibited (SILENCE).
A c t i v a t i o n o f u s e r l o a d s : s e e
" f i r s t s t a g e " o f f i l t r a t i o n c y c l e .
If not already running, the circulation
pump is activated for as long as the loads
remain active.
The message "ICE" appears in the
display while this function is in progress.
If the SWM function is active, the system
will not respond to a request for the
activation of user loads. If there is a user
load active, conversely, the SWM function
will be disabled and, if still required,
initiated 15 minutes after the user load
has switched off.
WHIRLPOOL PUMPS (pump 1 and
pump 2)
T h e w h i r l p o o l p u m p s c a n b e
activated from the keypad using the
r e l a t i v e c o n t r o l s ( Ti m e o u t 2 0 ' ) .
The control is an ON/OFF type.
Touching the 1 key pump 1 starts up;
touching the 1 key a second time, pump 2
starts up. The Led lights up green.
At power-up the pumps are disabled; once
the, minimum water level registers (L1=1),
the pumps are enabled. In the event of the
water level registering L1 = 0 (tub empty),
the pumps are disabled.
AIRPOOL (blower)
When included, the airpool function is
activated from the keypad using the 2